Skip to content
Victorian brick railway viaducts and an ornate iron bridge over the Bridgewater Canal at Castlefield, Manchester, with modern towers behind

Photo: Railway viaducts from Merchant's Bridge by DS Pugh · CC BY-SA 2.0 · cropped · source

United Kingdom · Manchester

Cross Connects and Carrier Circuits in Manchester

Reboot Monkey orders cross connects and carrier circuits in Manchester from the facility operator and the carriers present in the facility, and its engineers install and patch the cabling in the customer's rack. Work is quoted on request.

Cross Connects and Carrier Circuits

  • 14

    services detailed for Manchester

  • 1

    agreement for every city

Request Cross Connects and Carrier Circuits in Manchester

Tell Reboot Monkey which facility and rack the connection is for. Work is quoted on request and depends on the customer and the size of the job.

In depth

Cross Connects and Carrier Circuits: 7 sections, open any to read more.

Cross-connects and Carrier Circuits in Manchester

LINX reports a record maximum traffic peak of 725Gbps at its Manchester network fabric. LINX says its Manchester network delivers lower latency and more redundancy by keeping traffic local to the Manchester area. Equinix MA1 - Manchester, Williams/Kilburn stands on Manchester Science Park in Manchester. Reboot Monkey works inside data centres that other companies own and run: it is a third-party datacenter services operator, not a hosting company and not a datacenter owner. For a CTO, IT Director or procurement manager, the practical question in Manchester is how a new connection gets from the carrier to the customer's rack, and who does each step. Reboot Monkey sells the network for the rack. It takes on the ordering with the facility operator and the carriers, and its engineers do the physical cabling.

Datacenter Facilities in Manchester

Data centres in Manchester, ordered by the number of networks present:

  • Equinix MA1 - Manchester, Williams/Kilburn (Equinix, Inc.), Manchester Science Park, Lloyd Street North, M15 6SE: 109 networks; carriers Arelion, EDGOO NETWORKS, EXA Infrastructure, RETN and euNetworks
  • Equinix MA3 - Manchester, Joule House (Equinix, Inc.), 76 Trafford Park Road, Manchester M17 1HE: 51 networks; carriers EXA Infrastructure and euNetworks
  • Volta Manchester, Reynolds House, 4 Archway, Manchester M15 5RL: 40 networks; carriers Exascale, Inferno Communications, RETN and Rocket Fibre
  • Teledata Manchester - Delta House (Teledata UK Ltd), Delta House, Wavell Road, Manchester M22 5QZ: 34 networks; carriers Exascale and RETN
  • Equinix MA4 - Manchester, Synergy House (Equinix, Inc.), Synergy House, Manchester Science Park, M15 6SY: 33 networks; carriers EDGOO NETWORKS, EXA Infrastructure, RETN, Rocket Fibre and euNetworks
  • Pulsant Manchester NW-1, 1-2 Ball Green, Stretford, Manchester M32 0QT: 16 networks; carriers euNetworks
  • Pulsant Manchester NW-1: 1 MW of power capacity, 2N power, N+1 cooling (according to Pulsant).
  • ANS - MAN6 (ANS Group Limited), Unit 20a & 20b Blackmore Road, Cobra Court, Manchester M32 0QY: 10 networks; carriers Telcom Infrastructure Ltd
  • LDeX2 (iomart Hosting Limited), Unit 6, Waterside, Trafford Wharf Road, Manchester M17 1WD: 9 networks
  • ANS - MAN4 (ANS Group Limited), 2 Adbaston Road, Cobra Court, Manchester M32 0TP: 4 networks
  • iomart DC7 The Server Hotel Reynolds (Melbourne Server Hosting), Reynolds House, Archway, Manchester M15 5RL: 4 networks
  • iomart DC7 The Server Hotel Reynolds: PUE 1.5, N+1 cooling (according to iomart).

Our Cross-connects and Carrier Circuits Services

Each request is handled per facility. Reboot Monkey places the order with the facility operator and the carriers present in the facility. When the circuit is delivered, Reboot Monkey engineers install and patch the cabling in the customer's rack. The facility operator owns and runs the building, including its power, cooling and access policy, and Reboot Monkey engineers work under the operator's site rules. The scope of the service is as follows.

  • Cross connects and carrier circuits: ordered from the facility operator and the carriers present in the facility.
  • Cabling: Reboot Monkey engineers install and patch the cabling in the customer's rack.
  • Dark fibre and wavelengths: dark fibre between data centres and wavelength circuits, ordered from the carriers and quoted on request.
  • IP transit: offered as Economy, Premium and DDoS Premium plans, each quoted per data center for the capacity the customer needs.
  • Quotes: work is quoted on request and depends on the customer and the size of the job.

Why Reboot Monkey

Reboot Monkey sells connectivity together with the physical work around it, so the party that orders a circuit from the facility operator and the carriers is also the party whose engineers patch it in the customer's rack. As of 2026, Reboot Monkey's field engineers work in 190 countries and more than 400 locations. A second, briefed Reboot Monkey engineer is named as backup for every customer site. After a circuit is live, the Reboot Monkey NOC can monitor the customer's servers and network equipment as part of hardware monitoring. Customers who also need addresses can lease IPv4 addresses, alone or together with IP transit and rack space under one agreement. For a deployment that spans several sites, multi-site rollouts are one installation programme carried out at several of the customer's sites by Reboot Monkey engineers, under one agreement. Reboot Monkey does not host the customer's workload and does not own the building. It supplies the network and the engineers.

How Reboot Monkey Works

These terms apply in every facility in Manchester where Reboot Monkey engineers work.

  • Scope: Reboot Monkey orders cross connects and carrier circuits from the facility operator and the carriers present in the facility, and its engineers install and patch the cabling in the customer's rack.
  • Response: 1-hour, around-the-clock incident response SLA, and a 15 minute premium response available where technicians are stationed on-site, as a paid add-on. The incident response SLA covers incidents and unplanned requests; on-site, dispatch and resolution times, priority tiers, and planned or scheduled work are agreed per site in the service agreement.
  • Monitoring: 24/7 NOC monitoring across all facilities, covering IPMI, iDRAC, SNMP, temperature, power, network signals.
  • Hardware: vendor-neutral technicians for Dell, HP, Cisco, Juniper and Arista equipment.
  • Independence: independent from facility operators (not Equinix SmartHands, not NTT staff).
  • One agreement: single provider across cities, so a customer in several cities needs only one agreement.
  • Service levels and terms: https://www.rebootmonkey.com/en/solutions/sla
  • Published case study: a major ICT provider engaged Reboot Monkey for three full infrastructure rollouts in Lahore, Karachi and Islamabad, with the hardware installed the same day at every site. Read the case study at https://www.rebootmonkey.com/en/resources/case-study/how-we-completed-3-full-deployments-across-pakistan

Cross Connects and Carrier Circuits

The data centres we work in hold their own certifications, such as ISO/IEC 27001 and ISO 9001. Ask us for the certificate of your site.

Related Services

Connectivity rarely stands alone. A new circuit ends in a rack, so Colocation in Manchester covers rack space, and Rack and Stack in Manchester covers installing, mounting and cabling the new hardware that the circuit serves. Where a physical task is needed on the customer's instruction, such as a cable check or a reboot, Remote Hands in Manchester carries it out, while Smart Hands in Manchester takes technical work that needs diagnostic judgement and configuration knowledge. When equipment moves between racks, rooms or facilities, Server Migration in Manchester handles the move, and Data Center Migration in Manchester applies when a whole deployment changes location. For hardware that is being retired, Data Center Decommissioning in Manchester covers removing and disposing of it. For a full exit, datacenter exit and relocation combines the physical move of the customer's equipment with the removal and disposal of the hardware that is retired.

Frequently Asked Questions

What does cross-connects and carrier circuits cover in Manchester?

Reboot Monkey orders cross connects and carrier circuits from the facility operator and the carriers present in the facility, and its engineers install and patch the cabling in the customer's rack. Dark fibre between data centres and wavelength circuits are ordered from the carriers and quoted on request. IP transit is quoted per data center for the capacity the customer needs.

Do you work in every datacenter in Manchester?

Reboot Monkey engineers work in any facility in Manchester where the customer has equipment and access, under the operator's own access and safety rules. The customer adds the engineers to the facility's access list before the first visit.

How fast can Reboot Monkey respond in Manchester?

Incidents and unplanned requests are handled under a 1-hour, around-the-clock incident response SLA. There is also a 15 minute premium response available where technicians are stationed on-site, as a paid add-on. On-site, dispatch and resolution times, priority tiers, and planned or scheduled work are agreed per site in the service agreement.

How is Reboot Monkey different from the facility operator's own staff?

Facility operators' own technicians work for the building. Reboot Monkey engineers work for the customer: they are independent from facility operators (not Equinix SmartHands, not NTT staff), follow the customer's instructions, and the same team can cover several buildings in the city under one agreement.

How do I get started with cross-connects and carrier circuits in Manchester?

Send the site, the equipment and the task through the contact form. Reboot Monkey replies with a quote and an engineer plan for that facility. Once agreed, the customer adds the engineers to the facility's access list and the cross-connects and carrier circuits work is scheduled under the operator's rules.

Request Cross Connects and Carrier Circuits in Manchester

Tell Reboot Monkey which facility and rack the connection is for. Work is quoted on request and depends on the customer and the size of the job.

Published:

Get a quote