Cross Connects and Carrier Circuits

Cross Connect in Japan

Cross connects and carrier circuits in Japan are ordered from the facility operator and the carriers present in the facility. Reboot Monkey places the orders, and its engineers install and patch the cabling in the customer's rack, so the network reaches the equipment.

  • 12

    of our services in Japan

In depth

Cross Connects and Carrier Circuits: 6 sections, open any to read more.

Cross Connect in Japan: How It Works

Reboot Monkey sells the network for the rack. For equipment housed in a data centre in Japan, Reboot Monkey orders the cross connects and carrier circuits from the facility operator and the carriers present in the facility, and its engineers install and patch the cabling in the customer's rack. The work has two parts: the orders placed outside the rack, and the physical cabling inside it. Reboot Monkey carries both parts of the job.

Two kinds of order sit behind the term. A cross connect is ordered from the facility operator. A carrier circuit is ordered from a carrier present in the facility. Which of the two a deployment needs depends on what the rack has to reach, and a single project often needs both. The two orders go to different recipients, so a project that needs both involves the operator and a carrier. Separating them at the start of a request matters because it decides who receives the order.

A request begins with three details from the customer: the data centre in Japan, the rack, and the endpoint the link has to reach. The endpoint may be a carrier present in the facility, another party in the same building, or a service bought alongside the rack, such as IP transit or leased IPv4 addresses.

From that point the request follows three steps.

Installing and patching is physical work carried out in the customer's own rack, and Reboot Monkey engineers are dispatched to the customer's facility in Japan for it. Configuring the customer's switches or routers is a different kind of task: where it needs diagnostic judgement and configuration knowledge, it belongs to smart hands, which is technical work of exactly that kind. Keeping the two apart tells the customer what a cross connect order includes and what it does not.

When the rack itself is new, the cross connect order can be one part of a larger project. Rack and stack means installing, mounting and cabling new hardware. Rack and network design covers the rack layout and the network topology of a new or expanding deployment, and ends with documentation of the design and a controlled handover. The cross connect and carrier circuit orders for such a rack follow the same sequence as any other request.

For a rack that is already in service, a new link is a separate request. The order goes to the facility operator or the carrier in the same way, and the engineer installs and patches the new cabling in the existing rack.

Later changes follow the same route. A patch that has to move, or a cable that needs checking, is a new instruction to Reboot Monkey. Cable checks are among the physical tasks that remote hands covers, carried out on the customer's instruction.

  • The customer names the data centre, the rack and the endpoint to be connected.
  • Reboot Monkey places the order with the facility operator for a cross connect, or with the carrier present in the facility for a carrier circuit.
  • A Reboot Monkey engineer installs and patches the cabling in the customer's rack.

Datacenter Landscape in Japan

Data centres in Japan, ordered by the number of networks present:

  • Equinix TY8 - Tokyo (Equinix, Inc.), 2-1-7 Higashi-shinagawa, 140-0002 Tokyo: 151 networks; carriers BB Backbone, Global Secure Layer, Macarne, Orange Wholesale International - EVPL, RISE.ph and others
  • AT TOKYO (CC1/CC2) (AT TOKYO Corporation): 146 networks; carriers Arelion, BB Backbone, NTT ME, OneQode, RETN and others
  • Equinix TY2 - Tokyo (Equinix, Inc.), 3-8-21 Higashi-Shinagawa, 140-0002 Tokyo: 118 networks; carriers Arelion, BB Backbone, Global Secure Layer, Macarne, Orange Wholesale International - EVPL and others
  • Equinix OS1 - Osaka (Equinix, Inc.), 1-26-1 Shinmachi Nishi-ku, 550-0013 Osaka: 71 networks; carriers Arelion, BB Backbone, Hanshin Cable Engineering Co.,Ltd., JR West Optical Network(JRWON), Kintetsu Cable Network Co.,Ltd and others
  • Equinix TY6 - Tokyo (Equinix, Inc.), 2-2-43 Higashi-shinagawa, 140-0002 Tokyo: 68 networks; carriers BB Backbone, Global Secure Layer and Orange Wholesale International - EVPL
  • Equinix TY4 - Tokyo (Equinix, Inc.), Otemachi Finance City, 1-9-5 Otemachi, Chiyoda-ku, 100-0004 Tokyo: 63 networks; carriers BB Backbone, NTT ME, Rakuten Mobile and TOKAI Communications Corporation
  • NTT DATA Dojima (building #4) (NTT DATA CORPORATION), NTT DATA Dojima Bldg, Dojima 3-1-21 kita-ku, Osaka: 50 networks; carriers BB Backbone, Digital Edge Osaka Cross Link Service, Hanshin Cable Engineering Co.,Ltd., JR West Optical Network(JRWON), Kintetsu Cable Network Co.,Ltd and others
  • NTT DATA Otemachi Bldg (NTT DATA CORPORATION), NTT DATA Otemachi Bldg, Otemachi 2-2-2 Chiyoda-ku, Tokyo: 47 networks; carriers RETN and TOKAI Communications Corporation
  • Telehouse – TOKYO Otemachi (KDDI Otemachi) (Telehouse - Global Data Centers), Otemachi Building, Otemachi, Chiyoda-ku, 100-0004 Tokyo: 45 networks
  • Equinix TY7 - Tokyo (Equinix, Inc.), 2-2-43 Higashi-shinagawa, 140-0002 Tokyo: 39 networks; carriers Macarne and Orange Wholesale International - EVPL

Cross Connect in Japan: What We Deliver

Several services sit next to a cross connect order, and each has its own definition, so a buyer can see what belongs to the engagement and what belongs to a separate request. These are the closest neighbours:

Structured cabling and a cross connect both involve cabling in the customer's racks, but they answer different needs. A cross connect or carrier circuit is the ordered link, installed and patched into the customer's rack. Structured cabling is the cabling between the customer's racks and network equipment, including labelling.

A link inside one building and a link between two data centres are different orders. Inside a building, the order goes to the facility operator or to a carrier present there. Between data centres, dark fibre or a wavelength circuit is ordered from the carriers and quoted on request. The request should say which of the two is needed.

Moves change the order of work. Cross connects and carrier circuits are ordered from the operator and the carriers present in a given facility, so a move to another facility starts with new orders there. Server migration moves equipment between racks, rooms or facilities, and datacenter exit and relocation adds the removal and disposal of the hardware that is retired. At the destination, the cabling in the new rack is installed and patched by Reboot Monkey engineers.

For a GPU or AI cluster, racking, cabling and node swaps are one service, and the links that connect the cluster to a network are ordered as cross connects or carrier circuits.

The limits of the scope follow from who runs the building. The facility operator owns and runs the building, including its power, cooling and access policy, and Reboot Monkey engineers work under the operator's site rules. Rack-side cabling is where Reboot Monkey engineers carry out this service.

Requests that touch several sites in Japan can be arranged as multi-site rollouts: one installation programme carried out at several of the customer's sites by Reboot Monkey engineers. In that case the orders are placed with each site's facility operator and carriers.

  • Structured cabling: installing, labelling and patching the cabling between the customer's racks and network equipment.
  • Dark fibre and wavelengths: dark fibre between data centres and wavelength circuits, ordered from the carriers and quoted on request.
  • Hardware supply and spares: supply of data-centre hardware, servers, network equipment and spare parts, with spares kept in the customer's rack on request.
  • Server migration: moving equipment between racks, rooms or facilities.
  • Datacenter exit and relocation: the physical move of the customer's equipment to its new location together with the removal and disposal of the hardware that is retired.
  • GPU and AI cluster deployment: racking, cabling and node swaps.

Why Reboot Monkey for Cross Connect in Japan

Reboot Monkey is a third-party datacenter services operator. It sells rack space, IP transit, leased IP addresses, network, data-centre hardware and the services that deliver, install and support them. It is not a hosting company and it does not own datacenters.

For a procurement manager, the effect of that model is a single supplier across the rack, the network and the physical work. The cross connect order, the engineer who patches the cabling in the rack, and related services such as structured cabling, remote hands and hardware supply can all be requested from Reboot Monkey. Each request still starts from the facility, because the operator and the carriers are those present in that facility.

The network is sold with the rack rather than apart from it. Alongside rack space, Reboot Monkey offers IP transit as Economy, Premium and DDoS Premium plans, each quoted per data center for the capacity the customer needs. IPv4 addresses can be leased alone or together with IP transit and rack space under one agreement.

Work that recurs after the first installation can be agreed in advance. Remote hands retainers and hour blocks cover remote hands agreed as a retainer or as a block of hours for recurring work, with terms agreed per customer and quoted on request.

Two further services concern the equipment once it is in place. Inventory work records the customer's equipment in the data center by serial number, asset tag and rack position, against the customer's asset list. Hardware monitoring is the monitoring of the customer's servers and network equipment by the Reboot Monkey NOC.

Where a customer wants the infrastructure delivered and run for it, IT infrastructure turnkey and run applies: the customer or its investors fund the IT infrastructure, and Reboot Monkey buys, installs, configures and then runs it, inside the data center the customer chooses.

A second, briefed Reboot Monkey engineer is named as backup for every customer site. As of 2026, Reboot Monkey's field engineers work in 190 countries and more than 400 locations.

Prices are quoted on request and depend on the customer and the size of the job.

How Reboot Monkey Works

These terms apply in every facility in Japan where Reboot Monkey engineers work.

  • Scope: Reboot Monkey orders cross connects and carrier circuits from the facility operator and the carriers present in the facility, and its engineers install and patch the cabling in the customer's rack.
  • Response: 1-hour, around-the-clock incident response SLA, and a 15 minute premium response available where technicians are stationed on-site, as a paid add-on. The incident response SLA covers incidents and unplanned requests; on-site, dispatch and resolution times, priority tiers, and planned or scheduled work are agreed per site in the service agreement.
  • Monitoring: 24/7 NOC monitoring across all facilities, covering IPMI, iDRAC, SNMP, temperature, power, network signals.
  • Hardware: vendor-neutral technicians for Dell, HP, Cisco, Juniper and Arista equipment.
  • Independence: independent from facility operators (not Equinix SmartHands, not NTT staff).
  • One agreement: single provider across cities, so a customer in several cities needs only one agreement.
  • Service levels and terms: https://www.rebootmonkey.com/en/solutions/sla
  • Published case study: a major ICT provider engaged Reboot Monkey for three full infrastructure rollouts in Lahore, Karachi and Islamabad, with the hardware installed the same day at every site. Read the case study at https://www.rebootmonkey.com/en/resources/case-study/how-we-completed-3-full-deployments-across-pakistan

Cross Connects and Carrier Circuits

The data centres we work in hold their own certifications, such as ISO/IEC 27001 and ISO 9001. Ask us for the certificate of your site.

Frequently Asked Questions

What does cross-connects and carrier circuits cover in Japan?

In Japan, Reboot Monkey orders cross connects and carrier circuits from the facility operator and the carriers present in the facility. Its engineers then install and patch the cabling in the customer's rack. Dark fibre between data centres and wavelength circuits are separate services: they are ordered from the carriers and quoted on request.

Do you work in every datacenter in Japan?

Reboot Monkey engineers work in any facility in Japan where the customer has equipment and access, under the operator's own access and safety rules. The customer adds the engineers to the facility's access list before the first visit.

How fast can Reboot Monkey respond in Japan?

Incidents and unplanned requests are handled under a 1-hour, around-the-clock incident response SLA. There is also a 15 minute premium response available where technicians are stationed on-site, as a paid add-on. On-site, dispatch and resolution times, priority tiers, and planned or scheduled work are agreed per site in the service agreement.

How is Reboot Monkey different from the facility operator's own staff?

Facility operators' own technicians work for the building. Reboot Monkey engineers work for the customer: they are independent from facility operators (not Equinix SmartHands, not NTT staff), follow the customer's instructions, and the same team can cover several buildings in the country under one agreement.

How do I get started with cross-connects and carrier circuits in Japan?

Send the site, the equipment and the task through the contact form. Reboot Monkey replies with a quote and an engineer plan for that facility. Once agreed, the customer adds the engineers to the facility's access list and the cross-connects and carrier circuits work is scheduled under the operator's rules.

Order a cross connect in Japan

Tell Reboot Monkey the data centre, the rack and the endpoint, and the order is placed with the facility operator or the carrier.